Diagnostic Guide

E1

Bosch Refrigerator Error Code E1: Causes & Thermistor Fix

Appliance
Bosch Refrigerator
Primary Meaning
Fresh food compartment temperature sensor (thermistor) failure
Difficulty
Medium
Tools Needed

When a Bosch refrigerator displays the E1 error code, the control board has detected an open, shorted, or out-of-range signal from the fresh food (refrigerator) compartment temperature sensor (thermistor).

Because the control module relies on this sensor to cycle the compressor and damper motor, an E1 fault can lead to food freezing in the fresh food section, inadequate cooling, or continuous compressor operation.


What Causes Error Code E1?

  1. Damaged Thermistor Element: The NTC (Negative Temperature Coefficient) resistor inside the probe has failed open (infinite resistance) or shorted (near-zero resistance).
  2. Wiring Harness Issues: Pinched, severed, or corroded wiring between the sensor and the main electronic control module.
  3. Loose Terminal Connection: The terminal plug at the sensor housing or control board has backed out.
  4. Main Control Board Defect (Rare): The logic board is misinterpreting the sensor’s voltage return even though the sensor itself is healthy.

Step 1: Safety and Preparation

  1. Disconnect Power: Always unplug the refrigerator from the wall receptacle or switch off the dedicated circuit breaker before handling panels or wiring.
  2. Clear the Refrigerator: Empty the top and middle shelves of the fresh food compartment to allow unimpeded access to the sensor housing.

Step 2: Locate the Refrigerator Thermistor

On most Bosch freestanding and built-in models, the fresh food temperature sensor is located inside the interior cabinet:

  • Location: Typically mounted on the right or left interior side wall, concealed under a small vented plastic cover (about 1–2 inches wide).
  • Note: Certain bottom-freezer configurations house the evaporator defrost sensor behind the rear interior panel; however, code E1 specifically points to the cabinet air temperature sensor.

Carefully unclip the plastic sensor shroud using a flathead screwdriver or pry tool. Slide the probe out of its mounting clip.


Step 3: Test the Sensor with a Multimeter

Bosch uses NTC sensors, which increase in electrical resistance as temperature drops.

  1. Set your digital multimeter to the 20k Ohm (20,000 Ω) setting.
  2. Disconnect the sensor harness connector (or expose the two lead wires if connected directly).
  3. Touch one multimeter probe to each of the sensor’s metal terminals.
  4. Evaluate the Readings:
    • At Room Temperature (~77°F / 25°C): A healthy Bosch sensor typically reads approximately 4.5 kΩ to 5.0 kΩ.
    • At Fridge Temperature (~39°F / 4°C): The sensor should read roughly 9.5 kΩ to 11.0 kΩ.
    • In Ice Water (~32°F / 0°C): The resistance should measure between 13.0 kΩ and 16.5 kΩ.
    • Defective Reading: If the multimeter reads 0.00 (short circuit) or OL / 1 (open circuit / infinite resistance), the thermistor is dead and must be replaced.

Tip: If the resistance reading changes smoothly when you hold the probe in your warm hand, the sensor is actively responding to temperature shifts.


Step 4: Replacing the Sensor

If the multimeter confirms an abnormal reading or an open circuit, install a replacement Bosch OEM sensor kit.

  1. Cut or Unplug the Old Sensor:
    • If equipped with a modular quick-disconnect, unplug the defective probe.
    • If using a universal Bosch repair sensor kit, cut the defective sensor wires staggered (to keep the repair profile slim) at least 2 inches away from the wall opening.
  2. Strip the Wire Ends: Strip approximately 1/4 inch of insulation from each lead wire.
  3. Connect the Replacement Sensor:
    • Thermistors do not have polarity; it does not matter which wire connects to which lead.
    • Use waterproof heat-shrink butt splices or silicone-filled twist connectors to prevent moisture inside the fridge from corroding the junction.
  4. Re-mount the Sensor: Snap the new probe back into its holding bracket on the wall and reinstall the vented cover.

Step 5: Power On & Clear the Code

  1. Plug the refrigerator back into power.
  2. Allow the appliance 5 to 10 minutes to complete its self-check routine.
  3. The E1 error code should disappear automatically once the control board reads a normal resistance value from the new sensor.
  4. Set your fresh food compartment to the target temperature (e.g., 37°F or 3°C) and verify normal cooling over the next 24 hours.

Verified Video Walkthrough

Live Master Technician Available

Still Struggling to Resolve Error E1?

Ask a certified master diagnostic technician about your specific Bosch Refrigerator model. Get custom multimeter testing steps, wiring harness pinouts, and repair advice 24/7.

Ask a Verified Technician Online
✓ 24/7 Live Availability✓ Certified Field Engineers✓ 100% Satisfaction Guarantee