Diagnostic Guide
224Bosch Boiler Error 224: Flue Gas Limiter Tripped Fix
- Appliance
- Bosch Gas Boiler
- Primary Meaning
- Flue gas temperature limiter (thermostat) has tripped due to excessive exhaust heat or sensor fault
- Difficulty
- Medium
- Tools Needed
Error code 224 on a Bosch (or Worcester Bosch) gas boiler indicates that the flue gas temperature limiter (high-limit thermostat) has tripped. This safety device monitors the temperature of the exhaust gases exiting through the heat exchanger into the flue. If the flue gas temperature exceeds safety thresholds (typically over 105°C to 110°C depending on the model), the limiter breaks the safety circuit to prevent damage to the flue assembly and prevent dangerous operation.
This error is closely linked to general boiler overheating issues such as Error E9 (primary high limit tripped), but 224 specifically isolates the flue exhaust path. It can be caused by heat exchanger scale build-up, poor circulation, insufficient system pressure, or a malfunctioning limiter sensor.
Symptoms & Quick-Check
| Symptom / Behavior | Likely Culprit | Quick Check |
|---|---|---|
| Boiler shuts down abruptly after firing for 1-2 minutes | Restricted heat exchange / Lime scale | Listen for kettling/rumbling noises before lockout |
| Error 224 trips instantly on power-up | Tripped manual reset limiter or broken wiring | Check sensor switch continuity (Ohm test) while cold |
| Low system water pressure reading below 1.0 bar | Low water content causing rapid localized overheating | Inspect the boiler’s pressure gauge |
| Code appears with sluggish radiator heating | Primary circulation pump failure or airlock | Check if pump is spinning and bleed top radiators |
Step 1: Ensure Safety and Check System Pressure
Before opening any casing or inspecting electrical components:
- Switch off the electrical supply to the boiler at the external fused spur.
- Turn off the gas isolation valve if you suspect abnormal combustion.
- Check the primary system pressure gauge. If the pressure has dropped below 1.0 bar (optimal cold pressure is between 1.2 and 1.5 bar), open the filling loop to top up the system. Air pockets and low water can cause exhaust temperatures to spike drastically.
Step 2: Access and Inspect the Flue Gas Limiter
- Remove the front casing screws using the appropriate screwdriver and lift off the front panel.
- Locate the flue gas safety thermostat. It is mounted directly into the flue gas collector hood or near the top exhaust manifold above the primary heat exchanger.
- Inspect the two electrical lead connections to the sensor. Check for signs of melted insulation, corrosion, or loose spade connectors.
Step 3: Test the Flue Gas Limiter with a Multimeter
Most Bosch flue gas limiters are normally closed (NC) bi-metal switches or dedicated thermal fuses:
- Disconnect the electrical wiring harness from the two switch terminals.
- Set your digital multimeter to the lowest resistance setting (Ohms, Ω) or continuity beep mode.
- Place the meter probes across the two sensor terminals while the boiler is completely cold:
- Normal reading: Closed circuit showing near $0\ \Omega$ (less than $1.0\ \Omega$).
- Tripped/Faulty reading: Open Loop (OL or infinite resistance).
- If the device features a small manual reset button between the spade terminals, press it firmly until it clicks. Re-test continuity with the multimeter. If it resets and shows continuity, the switch tripped due to an actual high-heat event.
- If the switch remains open after attempting to reset, or if it is a non-resettable single-use thermal fuse, the component has burned out and must be replaced.
Step 4: Address the Underlying Overheating Cause
Resetting or replacing the sensor is only a permanent fix if you resolve why the exhaust gas overheated in the first place:
- Heat Exchanger Fouling: If combustion soot builds up on the exterior fins, or heavy limescale covers the inside water pathways, heat cannot transfer to the central heating water and escapes out the flue pipe. The heat exchanger will need chemical flushing or professional mechanical cleaning.
- Primary Circulation Issue: If the central heating pump is seized, airlocked, or failing to run, water remains stationary in the heat exchanger, rapidly turning to steam and driving flue temperatures above the 105°C threshold. Verify pump operation by removing the center bleed screw on wet-rotor pumps and checking that the shaft spins freely.
- Flue Restriction: Inspect the flue terminal outside the home to ensure leaves, bird nests, or structural blockages are not preventing smooth exhaust discharge.
Step 5: Resetting the Boiler
- Reconnect all wiring securely to the sensor terminals.
- Reinstall the boiler cover panels tightly to maintain room-sealed combustion chamber integrity.
- Restore power at the spur.
- Press and hold the Reset button (often marked with a crossed-out flame or ‘OK’) on the control fascia for approximately 3 to 5 seconds.
- The display should clear code 224 and return to standby or start the ignition sequence.
Note: Gas-related diagnostics, internal combustion seal removal, and flue path alterations must only be carried out by a certified gas safe technician.
Verified Video Walkthrough
Still Struggling to Resolve Error 224?
Ask a certified master diagnostic technician about your specific Bosch Gas Boiler model. Get custom multimeter testing steps, wiring harness pinouts, and repair advice 24/7.
Related Bosch Gas Boilers Error Codes
Bosch Gas Boiler 227: Bosch Gas Boiler Error 227: Flame Not Detected Fix Guide
No flame signal detected after ignition attempt (loss of ionization current).
Bosch Gas Boiler A5: Bosch Gas-Boiler Error A5: Causes & How to Fix
Flue gas temperature sensor (NTC) error or open circuit detected.
Bosch Gas Boiler D3: Bosch Boiler Error Code D3: Causes and Fixes
External temperature limiter (temperature monitor/bridge connection) has tripped or circuit is open
Bosch Gas Boiler D5: Bosch Boiler D5 Error: Causes and How to Fix It
D5 indicates an issue with the flow/supply temperature sensor (NTC sensor), showing an out-of-range temperature signal or open/short circuit.
Bosch Gas Boiler E9: Bosch Boiler Error E9: Safety Temp Limiter & Overheating Fixes
High-limit temperature limiter (safety thermostat) tripped due to overheating or low water circulation.
Bosch Gas Boiler EA: Bosch Boiler Error EA: Flame Not Detected (Diagnosis & Fixes)
Flame not detected. The boiler attempted ignition but failed to establish or sense a flame.